Fluorolog-QM
Home > Products > Horiba Jobin Yvon S.A.S

Modular Research Fluorometer for Lifetime and Steady State Measurements

The HORIBA Fluorolog-QM™ series of modular research grade spectrofluorometers is the fourth generation of the world famous HORIBA Fluorolog, with the first Fluorolog introduced by Spex Industries in 1975.
The Fluorolog-QM represents the culmination of decades of HORIBA’s industry-leading experience in development and manufacture of the highest level of spectrofluorometer performance and versatility. The Fluorolog-QM, with its exquisite, optically perfect, all reflective optics, combined with a multitude of light source and detector options, and sample handling accessories, provides the highest sensitivity and greatest versatility of any spectrofluorometer.
The Fluorolog-QM can be enhanced to suit a broad array of luminescence experiments, with the industry’s most extensive list of optional accessories to expand capabilities and performance, to meet all of the most demanding research lab’s experimental needs. And when you purchase a Fluorolog-QM all of these enhancements and accessories can be added to your system at any later time as your needs change, or funds become available.
With thousands operating in universities and research labs around the world, and tens of thousands of publications, Fluorolog has proved itself to be the best choice for the most demanding steady state, time-resolved, TCSPC, PLQY and NIR research.
Features
Unique Fluorolog-QM™ Benefits
Specifications
Signal-to-Noise Ratio >35,000:1 (FSD)
Data Acquisition Rate 1,000,000 points/sec. to 1 point/1000 sec.
Inputs 4 photon counting (TTL);
4 analog (+/- 10 volts);
1 analog reference channel (+/- 10 volts);
2 TTL
Outputs 2 analog (+/- 10 volts); 2 TTL
Emission Range with standard PMT 185 nm to 900 nm (optional to 5,500 nm)
Light Source High efficiency “ECO” friendly continuous 75 W Xenon arc lamp
(Optional 450 W Xenon)
Excitation and Emission Monochromators 700 mm, triple grating, coma-aberration corrected, asymmetrical, excitation or emission optimized,
Czerny-Turner design with computer controlled slits at entrance, intermediate plane and exit
Slits Computer controlled, continuously adjustable
Excitation Grating 1200 line/mm 300 nm blaze, (up to two optional gratings can be ordered)
Emission Grating 1200 line/mm 400 nm blaze, (up to two optional gratings can be ordered)
Wavelength Accuracy +/- 0.3 nm
Minimum Step Size 0.01 nm (grating dependent)
Standard Detection Multimode, -20 degrees Celsius cooled, 1600 Volt PMT housing;
Multimode: Photon Counting, 3 analog (fast, medium, slow response),
direct and Single-Shot Transient Digitizer (SSTD) mode,
and Time-Correlated Single Photon Counting (TCSPC), R928P PMT standard (other PMT's available)
R928P PMT Dark Count 10 counts per second or less
R928P PMT Maximum Linear Count Rate 10,000,000 counts per second
System Control Computer interface with FelixFL spectroscopy software
Lifetime Range 5 ps to seconds with appropriate time-resolved accessories
Applications
For Support Services