FluoroMax Plus
Home > Products > Horiba Jobin Yvon S.A.S
Steady State and Lifetime Benchtop Spectrofluorometer
The DeltaFlex time correlated single photon counting (TCSPC) system is one of our Delta series of next generation time correlated single photon counting lifetime instrumentation. The DeltaFlex offers the ultimate in flexibility.
The FluoroMax® Plus represents HORIBA’s industry-leading fluorometer performance in a convenient, affordable, easy-to-use benchtop model. The FluoroMax family, with its unique all reflective optics and photon counting was the first to bring the sensitivity of a modular fluorometer to a tabletop fluorescence instrument, in the 1990’s.
The FluoroMax® Plus represents HORIBA’s industry-leading fluorometer performance in a convenient, affordable, easy-to-use benchtop model. The FluoroMax family, with its unique all reflective optics and photon counting was the first to bring the sensitivity of a modular fluorometer to a tabletop fluorescence instrument, in the 1990’s.
The FluoroMax Plus is the latest generation of the original, high performance tabletop fluorometer, which offers extended performance with detection of emission spectra out to 1700 nm and (TCSPC) Time Correlated Single Photon Counting lifetime measurements as short as 25ps.
FluoroMax Plus spectrofluorometers are the most senstive, flexible and trusted benchotop spectrofluorometers in the world
Features
- Water Raman signal-to-noise ratio: 10,000:1 (FSD method)
- Photon Counting for Ultimate Sensitivity
- Photon Counting for Ultimate Sensitivity
- Powerful FluorEssence™ software for Windows®
- Method Files to recall complete experiment parameters
- Method Files to recall complete experiment parameters
- Phosphorimeter accessory for long-lived luminescence determinations
Specifications
| Lamp | Vertically mounted, CW, 150 W Ozone-free xenon arc lamp |
| Gratings |
1200 groove/mm blazed at 330 nm (excitation) and 500 nm (emission), plane ruled Automatic self-calibration of all wavelength drives and slits |
| Monochromators | All reflective optics, Czerny-Turner spectrometers |
| Detectors | Emission: R928P photon counting PMT (185-850 nm) and reference photodiode for monitoring lamp output |
| Water Raman S/N | 10,000:1 (FSD method). See Signal-to-noise ratio |
| Slits | Continuously variable from 0 to 29 nm |
| Accuracy | 0.5 nm |
| Repeatability | 0.1 nm |
| Minimum step | 0.0525 nm |
| Integration time | 0.001 to 160 sec |
| Software | FluorEssence |
| Spectral Correction Factors | Included |