TOP200 |
||
|
Analysis port(s) |
2 |
4 |
|
|
p0 Port(s) |
2 |
4 |
|
|
Number of micropore analysis stations |
UP TO TWO |
UP TO FOUR |
|
|
Adsorbates |
N2 , Ar, Kr, H2 , O2 , CO2 , CO, NH3 , CH4 , etc. |
||
|
Surface Area Range |
0.0001 m2/g to unknown upper limit; Measurement accuracy (standard sample) ≤ ± 1.0 % |
||
|
Pore Size Range |
0.35 nm – 500 nm(Options) Repeatability: ≤ 0.2 nm in mesopore range and ≤ 0.02 nm in micropore range |
||
|
Minimum Pore Volume |
0.0001 cm3/g |
||
|
Pressure Sensors (Individual sensor systems for each analysis port can be selected) |
1000 Torr, 10 Torr(Options) and 1 Torr(Options) or 0.1 Torr (Options), one extra 1000 Torr for p0 determination |
||
|
Pressure Sensor Accuracy |
± 0.15 % (Full Scale) |
||
|
Degassing Stations |
2 insitu |
4 insitu |
|
|
Degassing Temperature |
Room temperature to 400 °C (optional 500 °C), accuracy 1 °C |
||
|
Vacuum System |
Standard mechanical oil pump (ultimate vacuum 103 Pa), optional turbo molecular pump(ultimate vacuum 108 Pa) |
||
|
Independent vacuum system for each analysis port |
√ (Options) |
√ (Options) |
|
|
Dimensions |
|
|
|
|
Temperature Requirements of Environment |
15 – 40 °C |
||
|
Humidity Requirements of Environment |
10 % – 90 % |
||
|
Power Requirements |
AC 220 V ± 20 V, 50/60 Hz, maximum power 300 W, current 5 A |
||
|
Steam absorption |
√ |
× |
|
|
Independent Intake Gas System for Each Analysis port |
√ (Options) |
√ (Options) |
|
Top 200 Extensible Multi-Station Gas Adsorption Analyzer
Home > Products > Automatic BET Surface Area & Porosimetry Analyzer / Gas Adsorption Analyzer >Physisorption Analyzers: The AMI Physi Family >Top 200 Extensible Multi-Station Gas Adsorption Analyzer
AMI has re-incorporated many of the technical advantages of the adsorption field and launch the TOP-200 Extensible multi-stations gas adsorption analyzer. TOP-200 gas adsorption analyzer is compact and powerful, and can accurately test micropores, mesopores and surface area to study the adsorption behaviour of different adsorbates at different temperatures.
TOP series of instruments have a completely new internal structure, enabling the full independence of different analysis stations. At the same time, four analysis stations can complete four different gas adsorption experiments. The four stations can start the experiment separately and complete the experiment independently without waiting for each other
Hardware and Operation
- Specific surface area: >0.0001m2/g.
- Pore size: 0.35nm - 500nm.
- Power: 110~220V, 50/60Hz
Vacuum System
- Minimum relative pressure: 10-8, some samples are reached 10-9.
- Manifold: Multi-optimized design to provide the most suitable dead volume
- Flexible vacuum configuration:: Mechanical oil pump is standard. It can be upgraded to an independent turbomolecular pump for each analysis ports.
Techniques
Techniques
The analysis results for the top and quick series are included:
- Isotherm curve
- BET (Brunauer, Emmett, and Teller) surface area
- Langmuir surface area
- t-Plot
- Alpha-s method
- The BJH (Barrett, Joyner, and Halenda) method
- Dollimore-heal adsorption and desorption curve
- Dollimore-heal adsorption and desorption curve
- Horvath-Kawazoe (H-K)
- The MP method
- DFT
- NLDFT
- Dubinin-Astakhov (D-A)
- Dubinin-Radushkevich (D-R)
- Summary reports
- Custom reports Calculation model for heat of adsorption
Capabilities
- Physisorption
- Gas adsorption
- Gas sorption
- Nitrogen sorption
- Surface characterization
- Physisorption
- Gas adsorption
- Gas sorption
- Nitrogen sorption
- Surface characterization